Among its many features, labview also supports the ieee488 standard. Find the user manual for your chroma instrument here. Hi guys, i am trying to solve a problem related with chroma ac source and labview. Foothill ranch, ca prweb april 10, 2017 chroma systems solutions, inc. Chroma s 63600 series dc electronic loads are designed for testing multioutput ac dc power supplies, dc dc converters, chargers, batteries, adapters, and power electronic components. In windows 10, if an application is active or opened. Support worldwide technical support and product information national instruments corporate headquarters 11500 north mopac expressway austin, texas 787593504 usa tel.
By default, it sits at the bottom of your screen giving you access to the start menu, several application icons, and the notification area. Disconnect the usb cable when the onscreen battery icon shows full capacity. The ivi compliance package is based on and compliant with the latest version of the instrument programming specifications defined by the ivi foundation. As a system and application engineer, ive saved countless hours by automating measurements with software such as labview. Chroma s world leading ultra high power density design eliminates oversized and difficult to move high power electronic loads. This document will guide you through the steps for downloading and installing chroma instrument drivers for use with the national instruments labview development system on a windows operating system. Chroma ate 61601 ac source instrument driver national. With technical support groups available worldwide, chroma can provide automated test systems and the fabrication of test fixtures simultaneously at multiple locations across the globe. High speed dc load model 6330 series chroma model 6330 series high speed dc electronic improves cpu clock, baud rate, parser and added synchronic parallel function for fast operation, which is ideal for auto test system integration to increase your manufacturing test throughput. The high power ratings, parallel and synchronization capabilities make them the ideal tool for testing high power.
With its small footprint, it solves space issues when upgrading electronic loads in automated test systems. Yes, though it is somewhat more difficult than using agilent vees direct io object. The chroma 6310a series programmable dc electronic load is ideal for the test and evaluation of multioutput acdc power supplies, dcdc converters, chargers and power electronic components. Hipot tester 190711907219073 users manual for the outputted test voltage from zero rising to the specified value. Ivi getting started guide is intended for individuals who write and run programs. The 61600 ac power source offers output voltage from 0 to 300vac, and frequency from 15 to 1. I want to set chroma using parameters in the excel file then i am going to measure chroma paramaeters.
This paper describes gpib instrument control and data processing. The guide is part of the ivi foundations series of guides, getting started with ivi drivers. Provide a clear and comprehensive description of the problem and your question. Product quick guide pdf 6mb, ev test solution pdf 4. Pdf integrated testing of launch vehicle telemetry avionics. Ni vision assistant tutorial university of california.
When i just need to quickly take some measurements, python lets. Example programs are included with most instrument driver downloads. If all fields is set to x, all data fields in the dso are overwritten. Can labview communicate with agilent instruments without the use of instrument drivers. Use our ivi class drivers in conjunction with this driver to create interchangeable instrumentcontrol applications. The xg family programmable dc power supply is not intended for use in connection with life support systems or other medical equipment or devices. Rent or buy chroma 63201 dc electronic load, 2600w, 300a, 80v. In addition, the 63200a provides 4 sets of user defined hot keys that enable the user to enter operation. High speed dc electronic load 6330 series model no. Programmable dc power supply 62000h series operating. For use as a battery charger when you are using a power supply for battery charging applications, it is essential to provide an appropriately sized fuse or circuit breaker in series. The ivi compliance package includes ivi class drivers, simulation drivers, and examples for customers using ni programming environments with ivi.
The labwindowscvi ansi c integrated programming environment helps you create custom engineering applications. Having the misfortune of programing a chroma 63201 myself i would say you are better off not worrying about the missing dll because they are crap anyway. Can anyone offer any information on this or maybe point out where i have gone wrong. Bitter rick et al frontmatter labview advanced programming. Attach the type b connector of the usb cable to the usbtmc port on the standalone instrument and the type a connector of the usb cable to the usb port on the pc. Bitter, rick et al frontmatter labview advanced programming techinques boca raton. They are excellent for research, development, production, and incoming inspection applications. Crc press llc,2001 2001 crc press llc l ab view a dvanced p rogramming t echiniques rick bitter taqi mohiuddin matt nawrocki crc press boca raton new york london tokyo 2001 crc press llc preface and acknowledgments.
The chroma model 61600 series programmable ac power source delivers pure, instrument grade ac and dc power at very low cost. Hi, i am using chroma 636005 dc electronic load, and developing an application using labview 2011. Chroma agrees to repair or replace any assembly or component found to be defective, under normal use during this period. Although ive used it to build measurement applications, ive started to replace labview with python for basic lab measurements where i dont need develop an easytouse gui for. The chroma 6310a series programmable dc electronic load is ideal for the test and evaluation of multioutput ac dc power supplies, dc dc converters, chargers and power electronic components. Chromas 63200 series electronic loads can also simulate a short circuit condition.
Chromas obligation under this warranty is limited solely to repairing any such instrument. We present a chapter on multithreadings impact on labview. Dec 05, 2017 in this grade 12 robotics activity at blessed cardinal newman high school in scarborough on, two students joseph reyes and jude picache designed a vi virtual instrument using labview to. Homesupportdownloadsdrivers3rd party instrument drivers chroma ate 63201.
Chroma 63600 series modular dc electronic load quantel pte ltd. Testequity provides you with an excellent selection of test equipment to support your automotive applications. The labview instrument driver export wizard allows you to convert a labview 8. All chroma instruments are warranted against defects in material and workmanship for a. Support worldwide technical support and product information. It is designed for applications in research and development, production, and incoming inspection. Driver is supported on both 32 and 64bit platforms. The load can short a dc power supply or any power supplies that have a built in current limit function, and measure their short circuit currents so that users can verify if the uut current limit is functional.
Net learn how to use this driver with your environment. All of chromas instruments are warranted against defects in material and. One of the most important parts of your desktop is the taskbar. Labwindowscvi is an ansi c software development environment with a comprehensive set of programming tools for creating test and measurement applications.
Electronic load module, 060v, 30a,150 w dc, for n330x mainframes. Chroma 61604 programmable ac source 2kva chroma programmable ac power source 61600 series delivers pure, instrument grade ac power at very low cost. Testequity test and measurement equipment testequity. Power supplies are said to be regulated by controlling the output voltage or current to a. Chroma systems solutions to offer labview toolkits.
Request new driver request support learn more learn about instrument drivers development resources instrument control tutorials instrument control. This function is to change the time required for the outputted test voltage from the specified value falling to zero. Labview application builder libraries for sun runs on solaris 2. I was able to interface with this power supply using nivisa interactive control using the commands given in the power supply manual. It fits for testing multiple output switch power supply. Although ive used it to build measurement applications, ive started to replace labview with python for basic lab measurements where i dont need develop an easytouse gui for others to use. Connecting instruments via usb national instruments. Labview applications require an x windows system server, such as openwindows 3, hpvue, or x11r6. This is the final 1983 version as opposed to the 1982 version with arp schematics. Download chr63200a, a labview,measurement studio for visual studio,labwindowscvi usb ivi instrument driver for a dc electronic load from chromaate, models. Chroma instrument drivers for ni labview development system installation guide.
Do not operate your ichroma reader in close proximity of cellular or cordless. Chroma ate chr63200a electronic load usb driver for. Contact us to check availability and request a quick quote today. Integrated testing of launch vehicle telemetry avionics using pxi and ni labview. Changing the time for voltage falling this instrument contains fall function.
The chroma 6314 1200w and 6312 600w electronic load mainframes accept the userinstallable 6310 series load modules for easy system configuration and fit 19 instrument rack. Load module 40a80v200w chroma 6310 series programmable dc electronic load is suitable for the test and evaluation of multioutput acdc power supply, dcdc converter, charger and power electronics components and food for application in areas such as research and development, production, and incoming inspection. Scrap the chroma supplied drivers and write your own using the scpi commands in section 5 of the manual. Chroma s 63600 series dc electronic loads are designed for testing multioutput acdc power supplies, dcdc converters, chargers, batteries, adapters, and power electronic components. The labview instrument driver import wizard allows you to convert an instrument driver from labwindowscvi c source to a labview wrapper dll. This section contains the entire chroma service manual complete with large format schematics and drawings in pdf format. Be aware though that sometimes the quality of the drivers might not be that great. If the instrument is defective as a result of misuse, improper repair, or abnormal conditions or operations, repairs will be billed at cost. Chroma ate 63201 dc electronic load instrument driver.
I think, the source of this problem is chroma s set and measure blocks. As i am new to labview, i am not sure of much of its vi. Rent or buy chroma 63204 dc electronic load, 5200w, 100a. Rent or purchase a chroma 63204 dc electronic load, 5200w, 100a, 500v or 600v or other electronic loads for your testing requirements. Chroma is the global leader in electronic load manufacturing for product design validation and functional testing. Power supplies deliver electric power to a device or circuit electrical load, usually by stepping down a higher voltage. Chroma 61503 delay problem in labview ni community. I wanted to know whether i would be able to give these commands itself through labview. Ask the question you have about the blade chroma here simply to other product owners. Dc electronic load model 6310a series chroma ate inc. Every power supply has an input or supply power and converts it by various methods to meet the demand from the electrical load. The chroma 63202 dc electronic load is designed to test dc power sources, power electronic devices, automative battery and components testing.
Basics reading and writing tab delimited text files spreadsheet and text duration. Have you tried looking for the labview drivers for the chroma instruments. Chroma 63201 details chroma 63201 contact us to request a quote. Find instrument drivers that are available for this instrument for use in labview, labwindowscvi, or measurement studio. System overview discusses the overall architecture of the chroma. Labview measurements manual april 2003 edition part number 322661b01. Plugging the user selectable load modules into the system. All chroma instruments are warranted against defects in material and workmanship for a period of one year after date of shipment. Developing an application on labview to interface the camera. Page 5 this warranty does not apply to any products repaired or altered by persons not authorized by chroma, or not in accordance with instructions furnished by chroma. In my project, i am trying to automate a chroma power supply using labview like setting voltage, time, frequency. Advanced programmers understand the operation of the language they are working with and how it interacts with the system. Chroma 61604 programmable ac source 2kva tequipment. Chroma s 63201 programmable dc electronic loads are designed for a wide variety of dc power conversion products and are especially wellsuited for high power applications such as switchmode rectifiers and for discharging batteries packs and fuel cells.
The high power ratings, parallel and synchronization capabilities make them the ideal tool for testing high power uuts such as smrs, upss, batteries, and fuel cells. The 61600 series supplies output voltage from 0 to 300vac, and frequencies from 15 to hz. Ivi compliance package download national instruments. The ni vision assistant tutorial provides stepbystep instructions for. The better your problem and question is described, the easier it is for other blade chroma owners to provide you with a good answer.
This guide introduces key concepts about ivi drivers and shows you how to create a short program to perform a measurement. Intro to labview images and usb image acquisition and. Similarly refrain from throwing, shaking, dropping or mishandling the ichroma reader, which may damage its internal parts. High power dc electronic load 63200 series operation. Page 5 all chroma instruments are warranted against defects in material and workmanship for a period of one year after date of shipment. Chroma meter cs150 cs160 luminance meter ls150 ls160 instruction manual please read this manual before using the instrument. Jun 24, 2016 developing an application on labview to interface the camera andor ultra ixon. Dc electronic load 300a80v2600w the chroma electronic loads 63200 series are designed for dc power source, power electronic devices and components testing.
The 6314 holds four 63102 load modules at most to offer 8channel 100w input load with standard frontpanel inputs. Chroma programmable dc loads are used for power conversion testing in all markets including automated test systems, led drivers, power supply testing, battery testing, and fuel cell testing. Chroma 6310a series programmable dc electronic load quantel. A lot of device manufacturers provide labview drivers which give you a simple api to communicate with the device.
The guide also provides a brief introduction to several advanced topics. Labview tm measurements manual labview measurements manual april 2003 edition part number 322661b01. You can use it to manage your project, edit and debug source code, build a. I am running a 32bit version of labview 2014 on my windows 7 professional 64bit machine. Get datasheet weve been using the chroma 63208 electronic dc load for a number of applications. Apr 10, 2017 foothill ranch, ca prweb april 10, 2017 chroma systems solutions, inc. How to use commands given in the chroma manual in labview. These applications do not require a specific graphical user interface gui such as motif or openlook, because the program uses xlib to create its own gui. Once you get to the windows desktop screen, here are some basic features you will see.
937 563 94 664 580 331 1055 854 1432 1227 556 1230 362 1427 89 811 185 1302 811 105 633 1314 486 661 544 202 1381 1209 63 1062 750 762 856 1203 271 457 1307 509 323 975 1007 565 1318 518 692